How Can Boat Alarms and Equipment Status Be Brought Together on One Display?

Fire, bilge, motion and equipment status signals can connect to YatComm’s 16 digital inputs. See how they appear together in a real boat installation.

Several alarm sources on one boat

A fire detector, high bilge water sensor and pump running signal may all come from different equipment. Combining them into one general warning would leave an important question unanswered: which area needs attention? YatComm can monitor suitable alarm and status signals separately through 16 digital inputs on its main module.

Monitoring fire alarms by area

Smoke or heat detectors in the galley, saloon, cabins and engine room can be assigned to separate inputs. With five detectors, five areas can be identified by name while other inputs remain available for bilge and equipment signals. The detectors sense smoke or heat. YatComm receives their alarm signals, identifies the area on the display and can operate the connected siren through a configured output.

This arrangement can bring fire detection signals, area identification and siren control into the boat’s existing monitoring system. A separate panel used only for alarm indication and warning may therefore be unnecessary. Detector selection, siren, power supply and the boat’s safety requirements still determine the final installation.

What else can be connected?

Bilges and pumps

High water sensors can be fitted in different bilge compartments, with a separate input identifying each one. A pump running signal can be monitored on another input. The display can then show both the high water alarm and whether the pump is running, instead of assuming that a command to start the pump confirms operation. Where a pump provides a suitable fault contact, an overload or fault signal can also be monitored.

Access, power and equipment

Magnetic contacts can indicate an open hatch or door. A compatible motion detector can provide a movement alarm. A suitable monitoring relay can report whether shore power is present. A generator, inverter or other device can provide a fault signal if it offers an appropriate output. Gas and carbon monoxide detectors with alarm outputs are further possibilities. These are connection options selected according to the boat; they are not all presented as part of one completed installation.

What appears onboard and on the phone?

Inputs can be labelled clearly, such as “Engine room fire”, “Forward bilge high water” or “Shore power lost”. The relevant warning appears on the onboard display when an alarm is raised. Configured alarms can also reach the mobile app when the connection is available. A pump running or hatch open signal may be shown as status or treated as an alert, depending on how the boat is configured.

A real installation and input planning

In one published YatComm boat installation, three fire or smoke alarm signals from the galley, saloon and engine room, four high bilge water alarms, two pump running signals and pump overload signals were brought into the digital inputs. A fire alarm siren was connected to a control output. The five detector arrangement above illustrates how more inputs could be assigned to fire zones; it does not describe what was installed on that boat.

YatComm monitors 12/24 V digital input signals. Sensors wiring and the detector’s power supply must be arranged to provide a suitable signal to the input. Assigning a separate input to each signal preserves the ability to identify the area or equipment involved. Available inputs depend on what is already connected on the boat.

See the real installation’s input and output list. Read how remote alarm monitoring works to see how alerts reach the user, or contact YatComm to plan the inputs for your boat.